Loading...
45584901TH Rev.1
11-172 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
Mode
System Mainte-
nance
RDMS General 9724 Writingdataofself-
diagnostic code
0 0-1 SYS 0: Prohibited
1: Accepted
1
08 Setting
Mode
System Mainte-
nance
RDMS General 9726 Remote-service
initial registration
0 0-3 SYS 0: OFF
1: Start
2: Only certification is scanned
3: RDMS communication starts
1
08 Setting
Mode
System Mainte-
nance
RDMS General 9727 Remote-controlled
service tentative
password
- 10 letters SYS Maximum 10 letters 11
08 Setting
Mode
System Mainte-
nance
RDMS General 9729 Status of remote-
service initial regist
0 0-1 SYS 0: Not registered
1: Registered
2
08 Setting
Mode
System Mainte-
nance
RDMS Call /Display
function
9730 Service center call
function
1 0-2 SYS 0: OFF
1: Notifies all service calls
2: Notifies all but paper jams
1
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9732 Service center call
HTTPserverURL
setting
- - SYS Maximum 256 letters 11
08 Setting
mode
System Counter External counter 9736 Interrupt copying 0 0-1 SYS 0: Invalid
1:Valid
1
08 Setting
mode
System User
interface
Default mode setting 9738 Copy resolution
setting
0 0-1 SYS 0: 300dpi x 600dpi
1: 600dpi x 600dpi
1
08 Setting
Mode
System Mainte-
nance
RDMS Call /Display
function
9739 Toner-end
notification
0 0-2 SYS 0: RDMS toner empty notified immediately
1: RDMS toner empty notified once a day
2: RDMS toner empty not notified
1
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9740 HTTP proxy setting 1 0-1 SYS 0:Valid
1: Invalid
1
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9741 HTTP proxy IP
address setting
Refer
to
contents
- SYS Input IP address or FQDN.
<Default value>
0.0.0.0
11
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9742 HTTP proxy port
number setting
0 0-65535 SYS 1
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9743 HTTP proxy ID
setting
- - SYS Maximum 30 letters 11
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9744 HTTP proxy
password setting
- - SYS Maximum 30 letters 11
08 Setting
Mode
System Mainte-
nance
RDMS HTTP 9745 HTTP proxy panel
display
1 0-1 SYS 0:Valid
1: Invalid
1
08 Setting
mode
System Network Security 9746 802.1X/Dynamic
WEPselecting
button display
1 0-1 SYS Switches whether a selecting button for Security mode
802.1X/DynamicWEPisdisplayedornot.
0: Not displayed
1: Displayed
1

Table of Contents