211
Pulse Outputs Section 5-2
Changing Settings
Operation Example
application
Frequency changes Description Procedure
Instruction Settings
Change
speed in
one step
Changing
the speed in
one step dur-
ing operation
SPED(885) can be
executed during
positioning to
change (raise or
lower) the pulse
output frequency in
one step.
The target position
(specified number
of pulses) is not
changed.
PULS(886)
↓
SPED(885)
(Indepen-
dent)
↓
SPED(885)
(Indepen-
dent)
•Number of
pulses
•Relative or
absolute
pulse spec-
ification
•Port
•“CW/CCW”
or “Pulse +
direction”
•Indepen-
dent
•Target fre-
quency
Change
speed
smoothly
(with accel-
eration rate
= decelera-
tion rate)
Changing
the target
speed (fre-
quency) dur-
ing
positioning
(accelera-
tion rate =
deceleration
rate)
ACC(888) can be
executed during
positioning to
change the acceler-
ation/deceleration
rate and target fre-
quency.
The target position
(specified number
of pulses) is not
changed.
PULS(886)
↓
ACC(888) or
SPED(885)
(Indepen-
dent)
↓
ACC(888)
(Indepen-
dent)
•Number of
pulses
•Relative or
absolute
pulse spec-
ification
•Port
•“CW/CCW”
or “Pulse +
direction”
•Indepen-
dent
•Accelera-
tion and
decelera-
tion rate
•Target fre-
quency
PLS2(887)
↓
ACC(888)
(Indepen-
dent)
Change
speed
smoothly
(with
unequal
acceleration
and deceler-
ation rates)
Changing
the target
speed (fre-
quency) dur-
ing
positioning
(different
acceleration
and deceler-
ation rates)
PLS2(887) can be
executed during
positioning to
change the acceler-
ation rate, decelera-
tion rate, and target
frequency.
Note To prevent
the target
position from
being
changed
intentionally,
the original
target posi-
tion must be
specified in
absolute
coordinates.
PULS(886)
↓
ACC(888)
(Indepen-
dent)
↓
PLS2(887)
•Number of
pulses
•Relative or
absolute
pulse spec-
ification
•Port
•“CW/CCW”
or “Pulse +
direction”
•Accelera-
tion rate
•Decelera-
tion rate
•Target fre-
quency
•Starting
frequency
PLS2(887)
↓
PLS2(887)
Pulse
frequency
New target
frequency
Original target
frequency
Specified number
of pulses
(Specified with
PULS(886).)
Number of pulses
specified with
PULS(886) does
not change.
Execution of SPED(885)
(independent mode)
SPED(885) (independent
mode) executed again to
change the target
frequency. (The target
position is not changed.)
Time
New target
frequency
Original target
frequency
Specified
number of
pulses
(Specified with
PULS(886).)
Number of
pulses specified
with PULS(886)
does not
change.
Pulse
frequency
Execution of
ACC(888)
(independent
mode)
ACC(888) (independent
mode) executed again to
change the target
frequency. (The target
position is not changed,
but the
acceleration/deceleration
rate is changed.)
Time
Acceleration/
deceleration
rate
Pulse
frequency
New target
frequency
Original target
frequency
Specified number of
pulses (Specified
with PULS(886).)
Acceleration/
deceleration
rate
Execution of
ACC(888)
(independent
mode)
PLS2(887) executed to
change the target frequen-
cy and acceleration/decel-
eration rates.
(The target position is not
changed. The original tar-
get position is specified
again.)
Time