226
Pulse Outputs Section 5-2
a Origin Proximity Input Signal dog setting that is long enough (longer than
the deceleration time.)
Operating Mode 1 without Origin Proximity Input Signal Reverse (Origin
Detection Method Setting = 1)
Depending on the length of the deceleration time, the stopping position may
change when the Origin Input Signal is detected during deceleration.
Operating Mode 2 (with Error Counter Reset Output, with Positioning
Completed Input)
This operating mode is the same as mode 1, except the Positioning Com-
pleted Signal (INP) from the Servo Driver is used. Connect the Positioning
Completed Signal from the Servo Driver to a normal input (origin search 0 to 3
input).
1
1
0
0
CCW
CCW
CW
CW
Origin Proximity
Input Signal
Origin Input Signal
(Phase-Z signal)
Pulse output
Verify that the Origin Proximity Input
Signal's dog setting is long enough
(longer than the deceleration time.)
Origin Input
Signal is
ignored during
deceleration.
Motor stopped by an Origin
Input Signal received after
deceleration.
Starts when
ORG(889) is
executed.
Stop
Ideal time for the Origin Proximity Input
Signal to go OFF.
(Settings when the
deceleration time is short)
Stop (See note.)
Starts when ORG(889)
is executed.
Note: The Origin Input Signal can be detected immediately
after the Origin Proximity Input Signal goes from ON
to OFF if the deceleration time is short, e.g., starting
from within the Origin Proximity Input Signal.
1
1
0
0
CCW
CCW CW
CW
Origin Proximity
Input Signal
Origin Input Signal
(Phase-Z signal)
(The deceleration time is
relatively long in this case.)
Pulse output
(The deceleration time is short
in this case.)
Origin Input
Signal is
ignored during
deceleration.
Motor stopped by an Origin
Input Signal received after
deceleration.
Starts when
ORG(889) is
executed.
Stop
Motor stopped by an
Origin Input Signal
received after
deceleration.
Starts when
ORG(889)
is executed.
Stop