Serial Communications Section 6-3
For example, simple (non-protocol) communications can be used to input data
from a barcode reader or output data to a printer.
The following table lists the no-protocol communication functions supported
by CP1L PLCs.
CP1L CPU Unit
TXD(236) or RXD(235)
Sending/receiving data
RS-232C or RS422A/485
Standard device with
serial communications
(e.g., barcode reader)
Transfer direction Method Max.
amount
of data
Frame format Other functions
Start code End code
Data transmission
(PLC External device)
Execution of
TXD(236) in
the program
256 bytes Yes: 00 to FF
No: None
Ye s :
00 to FF or CR+LF
No: None
(The amount of data to
receive is specified
between 1 and 256 bytes
when no end code is speci-
fied.)
Send delay time
(delay between
TXD(236) execu-
tion and sending
data from specified
port): 0 to 99,990
ms (unit: 10 ms)
Controlling RS and
ER signals
Data reception
(External device PLC)
Execution of
RXD(235) in
the program
256 bytes Monitoring CS and
DR signals