640
Auxiliary Area Allocations by Address Appendix D
A351
to
A354
All Calendar/
Clock Area
These words contain the CPU Unit’s
internal clock data in BCD. The clock
can be set from the CX-Programmer
such as a Programming Console,
with the DATE(735) instruction, or
with a FINS command (CLOCK
WRITE, 0702).
--- Retained Retained Written
every cycle
---
A351.00
to
A351.07
Seconds (00 to 59) (BCD)
A351.08
to
A351.15
Minutes (00 to 59) (BCD)
A352.00
to
A352.07
Hours (00 to 23) (BCD)
A352.08
to
A352.15
Day of the month (01 to 31) (BCD)
A353.00
to
A353.07
Month (01 to 12) (BCD)
A353.08
to
A353.15
Ye a r (00 to 99) (BCD)
A354.00
to
A354.07
Day of the week (00 to 06) (BCD)
00: Sunday, 01: Monday, 02: Tues-
day,
03: Wednesday, 04: Thursday,
05: Friday, 06: Saturday
A360
to
A391
A360.01
to
A391.15
Executed FAL
Number Flags
The flag corresponding to the speci-
fied FAL number will be turned ON
when FAL(006) is executed. Bits
A360.01 to A391.15 correspond to
FAL numbers 001 to 511.
The flag will be turned OFF when the
error is cleared.
ON: That FAL
was executed
OFF: That
FAL wasn’t
executed
Retained Cleared Refreshed
when error
occurs.
A402.15
Address Name Function Settings Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words Bits