CX-Programmer_Page (xxv)
Unit Versions and Programming Devices
CX-Programmer version 4.0 or higher must be used to enable using the
functions added for CPU Unit Ver. 2.0. The following tables show the
relationship between unit versions and CX-Programmer versions.
Unit Versions and Programming Devices for CJ2 CPU Units
Required Programming Device
CX-Programmer
CPU Unit
Functions
Ver. 7.1
or
lower
Ver. 8.0 Ver. 8.1 Ver. 8.2 Ver. 8.3 Ver. 9.0 Ver. 9.1 Ver. 9.12
CJ2H-CPU6@-EIP
Unit version 1.0
Functions for unit
version 1.0
×
❍ ❍ ❍ ❍ ❍ ❍ ❍
CJ2H-CPU6@-EIP
Unit version 1.1
Functions added
for unit version
1.1
×
∆ ∆ ❍ ❍ ❍ ❍ ❍
CJ2H-CPU6@
Unit version 1.1
Functions added
for unit version
1.1
×
∆ ∆ ❍ ❍ ❍ ❍ ❍
CJ2H-CPU6@-EIP
Unit version 1.2
Functions added
for unit version
1.2
×
∆ ∆ ∆ ∆ ❍ ❍ ❍
CJ2H-CPU6@
Unit version 1.2
Functions added
for unit version
1.2
×
∆ ∆ ∆ ∆ ❍ ❍ ❍
CJ2H-CPU6@-EIP
Unit version 1.3
Functions added
for unit version
1.3
×
∆ ∆ ∆ ∆ ∆ ❍ ❍
CJ2H-CPU6@
Unit version 1.3
Functions added
for unit version
1.3
×
∆ ∆ ∆ ∆ ∆ ❍ ❍
CJ2M-CPU@@
Unit version 1.0
Functions for unit
version 1.0
×
× × × × × ❍ ❍
CJ2M-CPU@@
Unit version 2.0
Functions for unit
version 2.0
× × × × × × ∆ ❍
×: Cannot be used, ∆: Can be used except for new functions added for unit versions, ❍: Can be used
Note 1. It is not necessary to upgrade the version of the CX-Programmer if functionality that was
enhanced for the upgrade of the CPU Unit will not be used.
2. CX-Programmer version 8.1 or higher is required to use the functions added for unit
version 1.1. The high-speed interrupt function and changing the minimum cycle time
setting in MONITOR mode, however, are also supported by CX-Programmer version
8.02.
3. A Programming Console cannot be used with a CJ2H CPU Unit.