OMRON PART 1: CX-Programmer
CX-Programmer_Page (xxxv)
Version 3.2 Upgrade Information
The following tables outline the changes that have been made from version 3.1 to version 3.2 of the CX-
Programmer.
• New Models for Automatically Set Data Links
Previous version
(version 3.1)
New version (version 3.2)
With automatically set data links for Controller Link Networks, 1:N allocations are supported
in which data communications are set individually for the master node and slave nodes. (The
models that support this functionality are listed below.)
Any of the following four settings (data link patterns) can be used for automatic data links.
Equality layout (previous method), common type, 1 to 1 type, or chain type
• CS1W-CLK21-V1 • 3G8F7-CLK21-EV1
• CS1W-CLK12-V1 • 3G8F7-CLK12-EV1
• CS1W-CLK52-V1 • 3G8F7-CLK52-EV1
Applicable
models:
• CJ1W-CLK21-V1
With automatically set data
links, all nodes shared the
same data using the common
settings, i.e., the send size for
each node was the same, and
send/receive nodes were
always in the order of node
addresses.
Note: The 1:N allocations for automatic data links cannot be used with any other models.
Refer to the Controller Link Operation Manual for details.
Automatic Setting Procedure for Controller Link Networks
1. Go online with the PLC that is to be used as the polling node.
2. Select Data Link – Setup from the CX-Net.
If on the local network (i.e., if the network address is 0), select Controller Link and click the OK
Button.
The Data Link Component Dialog Box will be displayed.
3. Select Automatic Datalink Setup from the Online Menu.
Select Controller Link and click the OK Button.
The Automatic Datalink Dialog Box will be displayed.
4. In the Automatic Datalink Type Box, select Equality layout, Common type, 1 to 1 type, or Chain
type and set the automatic data link areas as shown below.
• Equality Layout (Previous Method)
This is the previous automatic data link type where all nodes are allocated the same sizes of data
links.
Settings Common to All Automatic Data Link Types
A
G
H
1
B
2
6
5
3
D
E
F
C
4
No. Item Description of function
A Generation
Type
Select Automatic. (If Manual is selected, data links will
be run using data link tables set separately.)
B Power Up
Run State
Select Start to automatically start data links when power
is turned ON to the PLC.
C Close Closes the Automatic Datalink Dialog Box.
D Read Reads the settings from the PLC.
E Write Writes the settings to the PLC.
(If the Power Up Run State is set to Start, the data links
will start running when the settings are written to the
PLC.)
F Help Displays help.
G Automatic
Datalink
Type
Select the type of data links to be automatically set up
from the following.
Equality Layout (Previous method)
Common Type (1:N settings)
1 to 1 Type (1:N settings)
Chain Type (1:N settings)
H Result The status is displayed when the Read or Write Button is
clicked.