4 Parameter List
4 - 20
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Auxiliary
function
b075
Ambient Tempera-
ture
10. to 50.
40
Enabled
°C
P. 7-87
b078
Integrated Power
Clear
00: Clear disabled
01: Clear with the Enter key
00
Enabled
P. 7-9
b079
Integrated Power
Display Scale
1. to 1000.
1.
Enabled
b082
Starting
Frequency
0.01 to 10.00 (100.00)
*1
1.50
Enabled
Hz
P. 7-35
b083
Carrier Frequency
2.0 to 15.0 or 10.0 (Heavy load/Light
load) (2.0 to 10.0)
*1
This parameter requires derating.
10.0/
2.0 (5.0)
*1
Enabled
kHz
P. 7-31
b084
Initialization Selec-
tion
00: Initialization disabled
01: Clearing Fault Monitor
02: Initialize data
03:
Clear fault monitor + Initialize data
04:
Clear fault monitor + Initialize data +
Clear DriveProgramming
00
Disabled
P. 5-5
b085
Initialization Data
Selection
Do not change from 00.
00
Disabled
b086
Frequency Conver-
sion Coefficient
0.01 to 99.99
1.00
Enabled
P. 7-6
b087
STOP Key Selection
00: Enabled
01: Disabled
02: Only RESET enabled
00
Enabled
P. 5-41
b088
Free-run Stop Selec-
tion
00: 0-Hz restart
01: Frequency pull-in restart at shutoff
02: Frequency pull-in restart
00
Enabled
P. 5-38
b089
Automatic Carrier
Reduction
00: Disabled
01: Enabled (dependent on current)
02: Enabled (dependent on cooling fin
temperature)
01
Enabled
P. 7-32
b090
Usage Rate of
Regenerative Brak-
ing
0.0: Regenerative braking not active 0.1
to 100.0 (limited by setting in b097)
0.0
Enabled
%
P. 5-64
b091
Stop Selection
00: Deceleration stop
01: Free-run stop
00
Enabled
P. 5-38
b092
Cooling Fan Operation
00: Always enabled
01:
Enabled only during operation (includ-
ing 3 minutes after power-on and 3 min-
utes after Inverter operation stop)
02: Dependent on fin temperature
01
Enabled
P. 7-86
b093
Total Fan Operation
Time Clear
00: Clear disabled
01: Clear (Set at time of replacement)
00
Enabled
b094
Initialization Target
Setting
00: All data
01: All data other than terminals/com-
munications
02: U*** registration function only
03:
Other than U*** registration function
and b37
00
Disabled
P. 5-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC