4 Parameter List
4 - 21
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Auxiliary
function
b095
Regenerative Brak-
ing Selection
00: Disabled (Function not active)
01: Enabled (Disabled during stop)
02: Enabled (Enabled during operation
and stop)
00
Enabled
P. 5-64
b096
Regenerative Braking
ON Level
200-V class: 330. to 400.
400-V class: 660. to 800.
360./720.
Enabled
V
b097
Braking Resistor
Value
Minimum connection resistance to 600.0
Mini-
mum
resis-
tance
Enabled
b098
Ground Fault Detec-
tion Selection
*1
00: Disabled
01: Enabled
01
Disabled
P. 7-92
V/f free function
b100
Free V/f
0.: Disabled
0.
Disabled
Hz
Frequency 1
1. to Free V/f Frequency 2
b101
Free V/f Voltage 1
0.0 to 800.0
0.0
Disabled
V
b102
Free V/f
Frequency 2
0.: Disabled
Free V/f Frequency 1 to Free V/f Fre-
quency 3
0.
Disabled
Hz
b103
Free V/f Voltage 2
0.0 to 800.0
0.0
Disabled
V
b104
Free V/f
Frequency 3
0.: Disabled
Free V/f Frequency 2 to Free V/f Fre-
quency 4
0.
Disabled
Hz
b105
Free V/f Voltage 3
0.0 to 800.0
0.0
Disabled
V
b106
Free V/f
Frequency 4
0.: Disabled
Free V/f Frequency 3 to Free V/f Fre-
quency 5
0.
Disabled
Hz
P. 5-9
b107
Free V/f Voltage 4
0.0 to 800.0
0.0
Disabled
V
b108
Free V/f
Frequency 5
0.: Disabled
Free V/f Frequency 4 to Free V/f Fre-
quency 6
0.
Disabled
Hz
b109
Free V/f Voltage 5
0.0 to 800.0
0.0
Disabled
V
b110
Free V/f
Frequency 6
0.: Disabled
Free V/f Frequency 5 to Free V/f Fre-
quency 7
0.
Disabled
Hz
b111
Free V/f Voltage 6
0.0 to 800.0
0.0
Disabled
V
b112
Free V/f
0.: Disabled
0.
Disabled
Hz
Frequency 7
Free V/f Frequency 6 to 590.
*2
b113
Free V/f Voltage 7
0.0 to 800.0
0.0
Disabled
V
4
4-3 Extended Function Mode
4-3-2 Group b: Detailed Function Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC