Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Multi-function Input 4 Selec- tion
00 to 09, 11 to 16, 18 to 24, 27
to 29, 31 to 42, 44, 46, 47, 50
to 53, 56 to 62, 65 to 70, 73,
78, 81 to 86, 91
255: no
00 to 09, 11 to 16, 18, 20 to 24,
27 to 29, 31 to 42, 44, 46, 47,
50 to 53, 56 to 62, 65 to 70,
73, 81 to 86, 91
255: no
Arrival Frequency During Accel-
eration 1
0.00 to 400.00 (580.00)
*1
Arrival Frequency During Decel-
eration 1
0.00 to 400.00 (580.00)
*1
Arrival Frequency During Accel-
eration 2
0.00 to 400.00 (580.00)
*1
Arrival Frequency During Decel-
eration 2
0.00 to 400.00 (580.00)
*1
Origin Search Mode 2 Fre-
quency
0.00 to 400.00 (580.00)
*1
*1. In high-frequency mode.
From Soft Lock Selection (b031) of the 3G3MX2-E Series Inverter, 10 (Data can be changed during
RUN) selection is deleted, and Data can be changed during RUN is always enabled.
To prevent unintended changes to parameters, use the Soft Lock Selection (b031). (Refer to 7-6-1 Soft
Lock Function (SFT) on page 7-54). To prevent unintended changes, use the password function (refer
to 7-6-9 Password Function on page 7-57).
However, it is not possible to write-protect only a portion of the parameters.
The 3G3MX2-EV2 Series Inverter allows you to change the following parameters during RUN, although
the 3G3MX2-E Series Inverter does not allow it. For parameters for which you can change data during
RUN, refer to the lists in Section 4 Parameter List.
2-step Acceleration Frequency
2-step Deceleration Frequency
Starting Voltage on Power Interruption
Deceleration Hold Level on Power Interruption
Deceleration Time on Power Interruption
Deceleration Starting Width on Power Interruption
Total Fan Operation Time Clear
PM Motor Starting Current
Speed Limit Value in Torque Control (Forward)
Speed Limit Value in Torque Control (Reverse)
Position Store Selection at Power Off
Position Data at Power Off
Modbus Mapping Function Selection
Modbus Mapping
External Register 1 to 10
Data can be changed during RUN