7-1-16 Reading and Setting the Clock
This
operation is used to read or set the CPU’
s clock. The clock can
be read in
any mode, but it can be set in MONITOR or PROGRAM mode only.
The
CPU will reject entries outside of the acceptable range, i.e., 01 to 12 for the
month,
01 to 31 for the day of the month, 00
to 06 for the day of the week, or 00 to
60 for the seconds, but it will not recognize non-existent dates, such as 2/31.
The
display will monitor the current date and time.
Press the Up and Down Arrow keys to move the
cursor through the data and time settings. Input
new values to change settings if necessary
.
Press CLR to return to the initial display
.
00000
TIM CHG?93-01-06
14:26:01 FRI(5)
TIM CHG?93-01-06
14:26:00 FRI(5)
TIM CHG?93-01-06
14:25:59 FRI(5)
TIM CHG?93-01-06
14:25:58 FRI(5)
TIM 93-01-06
14:25:57 FRI(5)
00000
Press
CLR to bring up the initial display
.
Press CHG to change the date and/or time. The “9”
in “93” will blink, indicating that it can be changed.
In this case, a “0” was input to replace the “8”.
FUN
7-1-17 Expansion Keyboard Mapping
This operation is used to control the ON/OFF status of bits SR 27700 through
SR 27909 by pressing keys on the Programming Console’s keyboard. The
C200HS also supports the C200H’s Keyboard Mapping operation, which con-
trols
the status of bits in AR 22. These operations can be performed in any PC
mode,
but the Programming Console must be in TERMINAL or expansion TER
-
MINAL mode.
To enable expansion keyboard mapping, pin 6 of the CPU’s DIP switch and
AR 0709 must be ON and AR 0708 must be OFF.
Bits
turned ON with this operation can be turned OFF by toggling AR 0708. T
urn
AR 0709 OFF to stop expansion keyboard mapping and switch the Program-
ming Console from Expansion TERMINAL mode to CONSOLE mode.
TERMINAL Mode The
Programming Console can be put into TERMINAL mode by pressing CHG
or
executing TERM(48) in the program.
Pin 6 of the CPU’
s DIP switch must be
OFF.
Switch
the Programming Console to TERMINAL
mode by pressing CHG or executing TERM(48).
PROGRAM BZ
<MESSAGE>
NO MESSAGE
PROGRAM BZ
CONSOLE
mode
Press CHG again to return to CONSOLE mode.
Example
Monitoring Operation and Modifying Data Section 7-1

Table of Contents

Other manuals for Omron SYSMAC C200HS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C200HS and is the answer not in the manual?

Omron SYSMAC C200HS Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C200HS
CategoryController
LanguageEnglish

Related product manuals