EasyManuals Logo

Omron SYSMAC C200HS User Manual

Omron SYSMAC C200HS
503 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #418 background imageLoading...
Page #418 background image
413
Note If
data is specified for writing which exceeds the allowable range, an error will be
generated
and the writing operation will not be executed. If, for example, 510 is
specified
as the beginning word
for writing, and three words of data are speci
-
fied,
then 512 will become the last word for writing data, and the command will
not be executed because TC 512 is beyond area boundary.
11-3-13 DM AREA WRITE –– WD
Writes data to the DM area, starting from the specified word. Writing is done
word by word.
Command Format
@
WD
FCS
x
10
1
x 10
0
x 10
3
x 10
2
: ↵
x 10
1
x 10
0
x 16
3
x 16
2
x 16
1
x 16
0
Node
no.
Header
code
Beginning word
(0000 to 9999)
W
rite data (1 word)
W
rite data
(for number of words to write)
Terminator
Note DM
6656 to DM 6999 do not exist. An error will not, however
,
result if you try to
write to these words.
Response Format
@ WD
x
10
1
x 10
0
x 16
1
x 16
0
: ↵
FCSNode
no.
Header
code
TerminatorEnd
code
Parameters Write Data (Command)
Specify
in order the contents of the number of words to be written to the DM
area
in hexadecimal, starting with the specified beginning word.
Note 1. If data is specified for writing which exceeds the allowable range, an error
will
be generated and the writing operation will not be executed. If, for exam
-
ple,
9998 is
specified as the beginning word for writing, and three words of
data
are specified, then 10000 will become the last word for writing data, and
the
command will not be executed
because DM 10000 is beyond the write
-
able range.
2. Be
careful about the configuration of the DM area, as it varies depending on
the CPU model.
11-3-14 AR AREA WRITE –– WJ
Writes
data to the AR area, starting from the specified word. W
riting is done word
by word.
Command Format
@
WJ
FCS
x
10
1
x 10
0
x 10
3
x 10
2
: ↵
x 10
1
x 10
0
x 16
3
x 16
2
x 16
1
x 16
0
W
rite data
(for the number of words to write)
W
rite data (1 word)
Beginning word
(0000 to 0027)
Node
no.
Header
code
Terminator
Response Format
@ WJ
x
10
1
x 10
0
x 16
1
x 16
0
: ↵
FCS
Node
no.
End code
Header
code
Terminator
Host Link Commands
Section 11-3

Table of Contents

Other manuals for Omron SYSMAC C200HS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C200HS and is the answer not in the manual?

Omron SYSMAC C200HS Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C200HS
CategoryController
LanguageEnglish

Related product manuals