Manuale d’uso - MCM260X - 115
11.1.5 Communication Cycle Period
Questo oggetto contiene il tempo massimo (msec) tra due messaggi SYNC (risoluzione 2msec). Se il
valore è 0, non c’è monitoraggio con SYNC.
Index Subindex Nome Tipo Default R/W
0x1006 0
Communication
Cycle Period
32bit unsigned 0 R/W
11.1.6 Manufacturer Device Name
Index Subindex Nome Tipo Default R/W
0x1008 0
Manufa cturer Device
Name
String M260 CONST
11.1.7 Manufacturer Hardware Version
Index Subindex Nome Tipo Default R/W
0x1009 0
Manufacturer
Hardware Version
String
Actu al hardware
version
CONST
11.1.8 Manufacturer Software Version
Index Subindex Nome Tipo Default R/W
0x100A 0
Manufacturer
Software Version
String
Actual software
version
CONST
11.1.9 Node ID
Index Subindex Nome Tipo Default R/W
0x100B 0 Node ID 8bit unsigned 0 R
11.1.10 Guard Time
Questo oggetto definisce il Guarding Time (tempo tra due interrogazioni, in msec).
Index Subindex Nome Tipo Default R/W
0x100C 0 Guard Time 16bit unsigned 0 R/W
11.1.11 Life Time Factor
Questo oggetto è parte del protocollo Node Guarding. Se uguale a 0, non viene eseguito alcun
monitoraggio.
Index Subindex Nome Tipo Default R/W
0x100D 0 Life Time Factor 8bit unsigned 0 R/W
11.1.12 Store Parameters
Questo oggetto salva i parametri utente permanentemente se la stringa
“save”
(ASCII 0x65766173)
viene scritta nel Su-index 1.
Index Subindex Nome Tipo Default R/W
0x1010 0 Numero di sub-index Array 8bit unsigned 1 R
1 Store all parameters Array 32bit unsigned
1 (stringa
“save”
per salvare)
R/W