EasyManua.ls Logo

Planet IGSW-24040T - Di_Act; Di_Desc; DIDO Command

Planet IGSW-24040T
521 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s Manual of IGSW-24040T
6.23 DIDO Command
Di_act
Description:
Digital input fuction and action configuration.
Syntax:
di_act [first|second] [1|2|3|4] [enable|disable]
Parameters:
<first >: Digital input/output 1
<second>: Digital input/output 2
(default: Set or show digital input/output first(1)/second(2) select)
<1>: System Log
<2>: Syslog
<3>: SNMP Trap
<4>: SMTP
(default: set or show digital input 1/2 action)
<enable>: Enable digital input1/2 function
<disable>: Disable digital input1/2 function
(default: Set or show digital input/output/fault alarm 1/2 status)
Example:
Enable Digital input 1 and enable acion to System log.
SWITCH/ >dido di_act first 1 enable
Didital input1 action
System Log:enbale
Syslog :disable
SNMP Trap :disable
SMTP :disable
Di_desc
Description:
Set or show the system digital input1/2 description.
490

Table of Contents

Other manuals for Planet IGSW-24040T

Related product manuals