Point Grey Flea3 USB 3.0 Technical Reference 1 Welcome to Flea3 USB 3.0
1.1.3 FL3-U3-13Y3M(Mono) Imaging Performance
Specification Mode 0
Full Well Depth 14500 e- at zero gain
Dynamic Range 52 dB
Read Noise 33 e- at zero gain
Measurements taken at maximum resolution
Quantum Efficiency
Peak QE Wavelength 560 nm
Peak QE Value 49%
Figure 1.3: FL3-U3-13Y3M Quantum Efficiency
Revised 9/27/2012
Copyright ©2011-2012 Point Grey Research Inc.
5