Point Grey Flea3 USB 3.0 Technical Reference 1 Welcome to Flea3 USB 3.0
1.1.4 FL3-U3-13E4M(Mono) Imaging Performance
Specification Mode 0
Full Well Depth 15600 e- at zero gain
Dynamic Range 54 dB
Read Noise 31.6 e- at zero gain
Measurements taken at maximum resolution
Quantum Efficiency
Peak QE Wavelength 570 nm
Peak QE Value 45%
Figure 1.4: FL3-U3-13E4M Quantum Efficiency