EasyManuals Logo

Polaris 850 SKS 155 2020 User Manual

Polaris 850 SKS 155 2020
747 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #639 background imageLoading...
Page #639 background image
10
9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
10.15
ADDITIONAL ROUTINGS
EGT SENSOR ROUTING
PIPE EGT SENSOR
1. The EGT sensor
q
is connected into the pipe. Route the EGT sensor wire toward the load center.
2. Take up some slack in the EGT sensor wire harness and secure to the load center bracket with a routing clip
w
.
3. Connect the EGT sensor connector
e
to the main harness connector.
BATTERY / ELECTRICAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris 850 SKS 155 2020 and is the answer not in the manual?

Polaris 850 SKS 155 2020 Specifications

General IconGeneral
BrandPolaris
Model850 SKS 155 2020
CategorySnowmobiles
LanguageEnglish

Related product manuals