enclosure
Usage
enclosure [-a <action>] -v
enclosure -a mod -s <list of settings>
enclosure -a locate [-t <FRU type> -f <FRU id>]
Summary
The enclosure command provides status and information about the various components of the enclosure unit. It
is also used to set thresholds for temperature and polling. In addition when using the -v option all VPD (Vendor
Provided Data) will be displayed.
Options
-a <action> Which action to perform.
list (Default) Displays information and status of the enclosure.
mod Allows the user to modify settings when coupled with the -s switch.
locate Allows the user to locate an enclosure by ashing LEDs
-e <encl id> Enclosure ID. The default value is 1 if unspecied.
For list action, the default is for all enclosures if unspecied.
-i <sensor id> IOM Sensor ID. For controller temperature warning (1..6) and critical
threshold. If unsepecied, only the IOM sensor 1,4 will be set, the IOM
sensor 2,3,5,6 will not changed.
-s “<option>=<value>” Used to specify which Enclosure settings to change.
Please note that IOM sensor 1 and 4 will always in same warning or
critical threshold settings. So changes on either sensor 1 or sensor 4
will take effected on both.
211
Promise Technology
Managing with CLI