- 16 -
After preliminary cleaning process stage, rinse the pane using running water first, distilled
next.
Avoid drying the panes either using paper towel or forced air circulation since some fibres,
grains or contamination of other type could permeate into the panes thus causing weighing
errors.
We do not recommend using driers when drying measuring glass tools.
It is a frequent treatment to leave glass components on a rack to dry.
Cleaning stainless steel components:
Avoid using cleansers containing any corrosive chemicals, e.g. bleach (including chlorine).
Do not use cleansers containing abrasive substances. Always remove the dirt using
microfiber cloth to avoid damage of protective coating.
In case of a daily maintenance:
1. Remove the dirt using cloth dipped in warm water.
2. For best results, add a little bit of dishwashing detergent.
Cleaning powder-coated components:
For preliminary cleaning process stage you need running water or wet sponge featuring
large holes, this will help you to remove loose, heavy dirt.
Do not use cleansers containing abrasive substances.
Next, using cloth and cleanser-water solution (soap, dishwashing liquid) gently rub the
cleaned surface.
Avoid using cleanser without water since it may result with damage of the cleaned surface,
please mind that large amount of water mixed with cleanser is a must.
Cleaning Aluminium Components
While cleaning aluminium components use products acid by nature, e.g. spirit vinegar,
lemon. Do not use cleansers containing abrasive substances. Avoid using hard brush, this
may cause scratches. It is recommended to use microfibre cloth.
While polishing the surface use circular movements. Use clean, dry cloth to make the
surface shine.
4.6. Connecting the Moisture Analyzer to the Mains
The moisture analyzer can be plugged to the mains only by means of an original
power cord, which comes standard with the instrument. Rated voltage (specified on
the device’s data plate) must be compatible with the mains rated voltage.
The power cord can be connected only to a socket with a ground contact. Plug the power
cord to the moisture analyzer. The moisture analyzer’s power plug is located at the back of
its housing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RADWAG MA X2.IC.A Series and is the answer not in the manual?

RADWAG MA X2.IC.A Series Specifications

General IconGeneral
BrandRADWAG
ModelMA X2.IC.A Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals