Chapter 4
46 OmniSeed™ Viper Pro™ Installation & Operation Manual
Cal. Proceed to the Bin Pressure Sensor Calibration section on page 47 to complete the bin pressure sensor
calibration.
Low Limit. Enter a value for the low limit to activate an alarm if the bin pressure (AIR) falls below the set value.
High Limit. Enter a value for the high limit to activate an alarm if the bin pressure (AIR) rises above the set
value.
Current Value (Cur. Val.). The current bin pressure is displayed in this area for any configured pressure
transducers.
Alarm. Enable the alarm option to provide an audible alarm if the bin pressure is outside of the range set by
the high or low RPM limits. If this selection is not enabled the Viper Pro will not provide an alarm.
Home Display. Select up to four items displayed on the Fan Calibration screen for display on the Viper Pro
main screen during field operations. This option allows the operator to monitor selected components of the
seeding system without returning to the Fan Calibration screen.
Note: If fewer than four items are selected for display on the main screen, the Viper Pro will randomly
select additional items for the home display.