MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
8540780 • 10/07/2020 • Rev.38 173
English
XOR
Logical XOR returns an output 0 (FALSE) if the
input's number at 1 (TRUE) is even or the inputs
are all 0 (FALSE).
In1
In2
Inx
Out
0
0
0
0
1
0
0
1
0
1
0
1
1
1
0
0
0
0
1
1
1
0
1
0
0
1
1
0
1
1
1
1
Parameters
Number of inputs: this is used to set between 2 and 8 inputs.
XNOR
Logical XNOR returns an output 1 (TRUE) if the
input's number at 1 (TRUE) is even or the inputs
are all 0 (FALSE).
In1
In2
Inx
Out
0
0
0
1
1
0
0
0
0
1
0
0
1
1
0
1
0
0
1
0
1
0
1
1
0
1
1
1
1
1
1
0
Parameters
Number of inputs: this is used to set between 2 and 8 inputs.