MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
8540780 • 10/07/2020 • Rev.38 19
RESTORE function
If the M1 or M1S unit is damaged, you can replace it with a new one; having already saved
all the configurations on the MCM, all you need to do is insert the MCM in the new M1/M1S
and switch on the MOSAIC system, that will immediately load the backup configuration. In
this way, the work interruptions will be minimized.
Compatibility between MCM memory and Master modules:
ï‚· M1S can load configurations from MCM if it is written by a M1S or M1
ï‚· M1 can load configurations from MCM only if it is written by a M1

The LOAD and RESTORE functions can be disabled via SW. (see Figure 54)
 Each time MCM is used, carefully check that the chosen configuration is the one that was
planned for that particular system. Try again a fully functional test of the system composed of
Mosaic plus all devices connected to it (see the "TESTING the system" section).