MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
8540780 • 10/07/2020 • Rev.38 207
English
Direction: This let the user to choose the order in which the sensors are occupied. If set to
BIDIR they can be occupied in both directions, from S1 to S4 and from S4 to S1, if set to UP
they can be occupied from S1 to S4 and if set to DOWN from S4 to S1.
Muting Closing: There are two types, CURTAIN and SENSOR. If you select CURTAIN muting
closes when the input signal rises, if you select SENSOR it closes when the third sensor has
been cleared.
Select CURTAIN
S1
S2
Input
S3
S4
Muting
0
0
1
0
0
0
1
0
1
0
0
0
1
1
1
0
0
1
Muting
active
1
1
X
0
0
1
1
1
X
1
0
1
1
1
X
1
1
1
0
1
X
1
1
1
0
0
0
1
1
1
0
0
1
1
1
0
0
0
1
0
1
0
0
0
1
0
0
0
Select SENSOR
S1
S2
Input
S3
S4
Muting
0
0
1
0
0
0
1
0
1
0
0
0
1
1
1
0
0
1
Muting
active
1
1
X
0
0
1
1
1
X
1
0
1
1
1
X
1
1
1
0
1
X
1
1
1
0
0
0
1
1
1
0
0
1
1
1
1
0
0
1
0
1
0
0
0
1
0
0
0
Blind Time: Only with Muting Close=Curtain, blind time is enabled when it is known that
after a complete transition of the pallet (muting cycle close) some protruding objects could
still occupy the light curtain and send the input to 0 (FALSE). During blind time the input
remains 1 (TRUE). Blind Time can range from 250 ms to 1 second.

Table of Contents

Other manuals for Reer MOSAIC MI8O4C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reer MOSAIC MI8O4C and is the answer not in the manual?

Reer MOSAIC MI8O4C Specifications

General IconGeneral
BrandReer
ModelMOSAIC MI8O4C
CategoryController
LanguageEnglish

Related product manuals