II Contents IndraControl L40
DOK-CONTRL-IC*L40*****-PR03-EN-P
6 Display and Operating Components 6-1
6.1 Display and Operating Keys ......................................................................................................... 6-1
6.2 Reset Button and Light-Emitting Diode ........................................................................................6-2
7 Connections and Interfaces 7-1
7.1 Overview of Connections on the Front .........................................................................................7-1
7.2 Voltage Supply.............................................................................................................................. 7-2
External Supply Voltages ........................................................................................................7-2
Internally Generated Voltages................................................................................................. 7-6
7.3 Digital Inputs and Outputs ............................................................................................................ 7-7
Address Assignment of Inputs and Outputs............................................................................ 7-7
Digital Onboard Inputs............................................................................................................. 7-8
Digital Outputs ......................................................................................................................... 7-9
7.4 Interfaces .................................................................................................................................... 7-12
Serial RS232 Interface ..........................................................................................................7-12
Ethernet Interface .................................................................................................................. 7-13
PROFIBUS DP (Optional) ..................................................................................................... 7-14
SERCOS (Optional)...............................................................................................................7-15
Ready Contact (Optional)...................................................................................................... 7-15
Interface for Compact Flash Card ......................................................................................... 7-16
7.5 Inline Bus .................................................................................................................................... 7-16
7.6 Function Modules ....................................................................................................................... 7-17
Overview................................................................................................................................ 7-17
Technical Data....................................................................................................................... 7-17
CFL01.1-Y1 SRAM Function Module.................................................................................... 7-19
CFL01.1-V1 DeviceNet Master Function Module.................................................................. 7-21
CFL01.1-P1 Profibus DP Master Function Module ............................................................... 7-23
CFL01.1-R3 SERCOS III Function Module........................................................................... 7-25
CFL01.1-Q2 Cross Communication Function Module........................................................... 7-26
CFL01.1-E2 Fast I/O Function Module.................................................................................. 7-27
CFL01.1-N1 Cam Switch Function Module........................................................................... 7-33
8 Installation and Maintenance 8-1
8.1 Mechanical Installation of the IndraControl L40 ........................................................................... 8-1
Mounting the IndraControl L40................................................................................................ 8-1
Dismounting the IndraControl L40........................................................................................... 8-3
8.2 Mechanical Installation of Rexroth Inline Modules ....................................................................... 8-5
Mounting the Inline Modules.................................................................................................... 8-5
Dismounting the Inline Modules .............................................................................................. 8-6
Fuse Replacement .................................................................................................................. 8-7
8.3 Electric Installation........................................................................................................................ 8-9
External Power Supply Unit..................................................................................................... 8-9
24 V Voltage Supply.............................................................................................................. 8-10
Main Switch and Fuses ......................................................................................................... 8-14
Ground Connection ...............................................................................................................8-15
Buy: www.ValinOnline.com | Phone: 844-385-3099 | Email: CustomerService@valin.com