SP Tables
M047 3-28 SM Appendix
5501
PM Alarm Interval
001
Printout
[0 to 9999 / 0 / 1 step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999) >= PM counter
5504
Jam Alarm
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3/3/1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
Error Alarm DFU
Sets the error alarm level.
[0 to 255 / 25 / 100 copies/ 1 step]
5507
Supply Alarm
5507 001 Paper Supply Ala(rm)
Switches the control call on/off for the paper
supply. DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified
number transfer sheets for each paper size
(A3, A4, B4, B5, DLT, LG, LT, HLT)
5507 004 MaintenanceKit
When switched on this function informs the
@Remote supply center that the
maintenance kit requires servicing.