M126/M127/M128 5-14 SM
Each button press moves the margin values one pixel in the respective direction.
14. Press "Submit" to accept the value.
15. Verify the changes by placing the print quick test page face down and touching Copy Quick
Test.
16. Repeat steps 13, 14,and 15 as needed.
To manually register the flatbed, perform the following steps:
1. In the Configuration Menu, touch the Scanner Manual Registration menu item.
2. Touch the Print Quick Test Page menu item.
3. To view and adjust the flatbed registration, place the quick test page into the flatbed.
4. Touch the Copy Quick Test Page item.
5. After the quick test page copies, touch Flatbed.
6. Use the
or to increase or decrease the settings value for the left or top margin.
Each button press moves the margin values one pixel in the respective direction.
7. Touch "Submit" to accept the value.
8. Place the print quick test page on the flatbed and touch Copy Quick Test.
9. Repeat steps 5 and 6 as needed.
To exit RESGISTRATION press "BACK"
or "STOP" .
5.2.19 DISABLE SCANNER
This menu item is used to disable the scanner if it is malfunctioning. The machine must be
powered off and on for the new settings to take effect.
To change this setting:
1. Touch "Disable Scanner" from the Configuration Menu.
2. Touch
or to scroll through the setting's other possible values. The settings are Enable,
Disable, ADF disable.
3. To save the setting's new value, touch "Submit".