Removal Procedures
SM 4-69 M126/M127/M128
Replacement
and
Adjustment
Right Side Cover Removal")
3. Disconnect the toner level sensor cable (A) from the engine board.
4. Squeeze the lower tabs (B) of the toner level sensor, and push it from its holder.
5. Toner level sensor (take it out through the inside of the printer).
The toner level sensor must be installed properly, or the printer will not function.
4.2.48 TOP COVER ASSEMBLY REMOVAL
1. Scanner assembly ( p.4-75 "Scanner Assembly Removal")
2. Lift off the top cover.
Be sure to lift the top cover assembly from the front to remove it.
During reinstallation, be sure the exit guide and the paper bin align correctly. A
mismatch can cause paper jams.
4.2.49 TRANSFER ROLL REMOVAL