M126/M127/M128  5-36  SM 
5.3.7  OUTPUT BIN TESTS 
Feed tests (output bins) 
Use these tests to verify that media can be fed to the standard output bin. No information is 
printed on the media fed to the output bin, because the printhead is not engaged during this test. 
These tests can use any media size or envelope supported by the machine. 
To run the Feed Tests for the output bins: 
1.  Touch 
  to select "Feed Tests" from the OUTPUT BIN TESTS. 
2.  Touch 
  to select the output bin you want the paper to exit into.   
3.  Touch 
  to select either Single or Continuous. 
  "Single"—feeds one sheet of media from the selected source. 
  "Continuous"—media continues feeding from the selected source until "Stop" 
  is 
pressed. 
Touch "Back" to return to OUTPUT BIN TESTS. 
Sensor test (standard output bin) 
This test is used to verify if the standard bin sensor is working correctly. 
To run the Sensor Test for the standard bin: 
1.  Touch 
  to select "Sensor Test" from OUTPUT BIN TESTS. 
2.  Touch 
  to select "Standard Bin" from Sensor Tests. 
3.  Manually actuate the bin sensor by moving the flag in and out of the sensor, and the display 
changes. The following screen is displayed: 
"Bin Empty: empty" or "Bin Empty: full". 
4.  Press "Stop" 
  to exit the test.