M126/M127/M128 6-36 SM
Error Description Action
845.01
Rear scan module cable failure or
SCC card failure
CCD channel failure. Check each
channel (mono, R, G, B) for identical
values indicating bad cable and/or
SCC card. Excessive noise test for the
dark data indicating some sort of CCD
or analog electronics issue on that
channel or channels (
p.6-90 "CCD
Service Check").
845.02 Cable / SCC Failure
Front scan module connector or cable
failure (
p.6-90 "CCD Service
Check").
845.03 Cable / SCC Failure
Rear scan module connector or cable
failure (
p.6-90 "CCD Service
Check").
845.yy CCD Failure
The CCD is defective (
p.6-90 "CCD
Service Check").
846 Front calibration strip unusable
p.6-90 "CCD Service Check"
846.01 Rear calibration strip unusable
846.02 Front calibration strip too far left
The font calibration strip is placed to
high or too low (
p.6-90 "CCD
Service Check").
846.03 Front calibration strip too far right
p.6-90 "CCD Service Check"
846.04
Front calibration strip has excessive
skew
846.05
Front calibration strip has excessive
bow
846.06
Front calibration strip has excessive
dark area
Front excessive variability for Mono,
Red, Green, or Blue (
p.6-90 "CCD
Service Check").