M126/M127/M128  6-54  SM 
FRU  Action 
LVPS/HVPS 
Verify main power to engine board 
With the machine off, unplug the LPS/HVPS cable at J502 
on the controller board. Verify grounds on pins 10, 12, 14, 
16 and 18 for both the cable and the engine board. If any of 
these grounds are incorrect, then check the cable for 
continuity. If the cable fails continuity, then call the next 
level of support. 
Turn the machine on with the cable still unplugged, and 
verify the following on the cable (engine board will not be 
powered): 
  6, 17, 19 (Pins): +24Vdc 
  1, 3-5, 7, 11, 13, 15 (Pins): +5Vdc 
If any of the voltages are incorrect, then replace the 
LVPS/HVPS (
p.6-57 "Dead Machine Service Check").