EasyManua.ls Logo

Roche URISYS 2400 - Test Parameters; Sieve and Abnormal Values

Roche URISYS 2400
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Roche Diagnostics
Operators Manual · Version 1.0 B-17
URISYS 2400 3 Software
Installation
Tes t parameters
a To set test parameters
1 Press <Menu> on the [Routine Monitor] screen. The [Menu] screen is
displayed.
2 Press <Parameters>. The [Parameters] screen is displayed.
3 Press <Test Parameters>. The [Test Parameters] screen is displayed.
4 Press any of the following five buttons to gain access to the option you
require:
o <Sieve & Abnormal>
o <Print Order>
o <Controls>
o <Range Table>
o <Units>
Sieve and abnormal
values
Use the sieve settings to define the criteria for a flag (S) on the corresponding
test parameter result. These flags can be used to identify urine samples to be
examined by additional methods, for example, sediment microscopy.
Use the abnormal settings to define the criteria that indicate potentially
pathological values. An asterisk (*) flags the corresponding test parameter
results.
The concentration values which are specified on the screen represent the
lowest concentration ranges from which on the test parameter results are
flagged.
For more information, see:
Table E-1 on page E-2
Figure B-9 Sieve & Abnormal screen

Table of Contents