Fitting the Options SME
1038.6002.02 1.11 E-13
1.3.10 Option SME-B12 - DM Memory Extension
The memory extension is mounted on one of rear slots A5, A6 or A12.
À Undo the board locking on both sides of the motherboard.
À Plug the PCB on one of the slots A5, A6, or A12.
À Fix the board locking.
1.3.11 Option SME-B19 - Rear Panel Connections for RF and LF
The SME can be retrofitted to include rear panel connections for RF and LF for mounting it into a 19"
rack using option SME-B19. The mounting instructions are attached to the option.
1.3.12 Options SME-B41 - FLEX Protocol - and SME-B42 - POCSAG
Options SME-B41 and SME-B42 are software options. They can be enabled by a keyword. The
keyword is printed on a label which is part of the equipment supplied and has to be stuck to the rear of
SME.
A prerequisite for installing the options is that option SME-B11 (DM Coder, hardware: VAR
4, REV
1)
and SME-B12 (Memory Extension, hardware: VAR
2, REV
2) as well as a firmware version
1.95
are part of SME.
Enabling option
À Call up menu UTILITIES-INSTALL and then press key [SELECT].
À Select OPTION TO INSTALL and then press key [SELECT].
À Select option (FLEX or POCSAG) to be installed and then press key
[SELECT].
À Enter the 6-digit keyword into the entry field INSTALLATION KEY
and then press [ENTER]
À Switch off unit and then switch on again.
After installation, the new option can be checked in the module list in menu UTILITIES-DIAG-CONFIG