8.12 Viewing the Data Storage Device
The data storage device stores weight values with date, time, and process number.
The content of the data storage device can be searched and sorted using a filter.
The data storage device has a ring buffer. This means that the oldest data records
can be overwritten by new ones. The data storage device is designed for a specific
number of data records (for the number of data records see Chapter “15.10 Data
Storage Device”, page 81).
The user alone is responsible for making sure that there is sufficient storage capacity
and the saved weighed values are present.
The data storage device is verifiable. The proper functioning of the data storage
device must be ensured for verification by saving and checking some values.
Procedure
t Open the “Settings / Device Settings / Device Information” menu.
t Press the “View data storage device” menu entry.
y A list of all the values saved in the data storage device is displayed.
t If only the values for a desired date need to be displayed:
t Press the [Filter] button.
t Type the desired date into the entry field.
t To filter the list with the date entered: Press the [OK] button.
t If the list needs to be searched for a particular ID:
t Press the [Search] button.
t Type the desired ID into the entry field.
t To start the search with the entered ID: Press the [OK] button.
8.13 Running Applications (Examples)
8.13.1 Executing the “Unit Change” Function
The “Unit Change” function enables the user to switch between the different units
and resolutions defined in the weighing profile of the active task. The units and
resolutions can be set at the beginning of the weighing process.
Procedure
t Start the desired task.
t Press the [Unit Change] button.
y All units defined in the weighing profile for the active task are displayed in a list.
y All resolutions for the weight value defined in the weighing profile for the active
task are displayed in a list.
t Press the desired unit.
t To set the resolution for the selected unit: Press the desired resolution.
t To confirm the selection and return to the weighing display: Press the [OK]
button.
y The current weight value is displayed in the selected unit and resolution.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius Cubis MCA10202S Series and is the answer not in the manual?

Sartorius Cubis MCA10202S Series Specifications

General IconGeneral
BrandSartorius
ModelCubis MCA10202S Series
CategoryScales
LanguageEnglish

Related product manuals