Designated use
Safety Notes
2.3 Designated use
The MOVISAFE
®
DCS21B option in combination with the DFS12B/22B option and the
MOVISAFE
®
DCS31B option are designed for installation in MOVIDRIVE
®
MDX61B
inverter sizes 1 to 7.
When installed in machines, startup of the MOVISAFE
®
DCS..B option (i.e. start of
designated operation) is prohibited until it is determined that the machine complies with
the local laws and directives. In the individual area of application, you must especially
observe the Machinery Directive 2006/42/EC as well as the EMC Directive
2004/108/EC. The EMC test specifications EN 61000-4-2, EN 61000-4-3, EN 61000-4-
4, EN 61000-4-6 and EN 61000-6-2 form the basis for this. EN 60204-1 must also be
observed.
You must observe the technical data and information on the connection requirements
as provided on the nameplate and in the documentation.
2.4 Transportation, storage
Observe the notes on transportation, storage and proper handling. Observe the climatic
conditions as stated in the section "General technical data".
2.5 Installation
The units must be installed and cooled according to the regulations and specifications
in the corresponding documentation.
Protect the MOVISAFE
®
DCS..B option from improper strain. Ensure that components
are not deformed and/or insulation spaces are maintained, particularly during transpor-
tation. Avoid contact with electronic components and contacts.
The MOVISAFE
®
DCS..B option contains components that can easily be damaged by
electrostatic energy and improper handling. Prevent mechanical damage or destruction
of electric components (may pose health risk).
The following applications are prohibited unless explicitly permitted:
Use in potentially explosive atmospheres.
Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc.
Use in non-stationary applications.

Table of Contents