Manual – MOVIDRIVE® MDX61B Safety Module MOVISAFE® DCS..B Option
3
Safety functions
Integrated Safety Technology
3.2.14 SCA – Safe Cam
The SCA function provides a safe signal to indicate whether the drive is located in a
specific area or position range. This signal can be displayed or used for programming.
Violation of the defined limit values will disable the safe signal.
2177370379
Safety function trips
v = Velocity
s = Distance
x
1
= Lower limit of range
x
2
= Upper limit of range
INFORMATION
The SCA function need not be acknowledged