Manual – MOVIDRIVE® MDX61B Safety Module MOVISAFE® DCS..B Option
75
6
General information on startup
Startup
Use parameters P555/P556 to set the response of option DCS21B to errors and
alarms to "DISPLAY FAULT" (see chapter "Parameter descriptions"). The set error
response will also be triggered in CONTROLLER INHIBIT inverter status.
Set the parameters for option DCS21B according to your application.
Program your fail-safe control according to your application.
Set the parameters for fieldbus connection via PROFIsafe (see chapter "Fieldbus
connection via PROFIsafe")
Perform a validation (see chapter "Validation"). Create a configuration report (see
chapter "Creating a configuration report").
6.1.3 Startup steps for DCS31B
Make sure that
Installation of the DCS31B option
the cabling,
the terminal assignment and
safe disconnection
have been configured correctly and are suited to the application.
Take suitable measures to prevent the motor from starting unintentionally. Take
additional safety measures depending on the application to prevent possible injuries
and damage to machines.
Switch on the line voltage and the DC 24 V supply voltage, if applicable.
Start up the drive with MOVIDRIVE
®
MDX61B as described in the "MOVIDRIVE
®
MDX60B/61B" operating instructions.
Use parameters P555/P556 to set the response of option DCS31B to errors and
alarms to "DISPLAY FAULT" (see chapter "Parameter descriptions"). The set error
response will also be triggered in CONTROLLER INHIBIT inverter status.
Program the DCS31B option according to your application.
Perform a validation (see chapter "Validation"). Create a configuration report (see
chapter "Creating a configuration report").