126 FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
Assembly and Installation
Subject to change without notice
● Substitutions of components
WARNING: Explosion Hazard
Substitutions of components may impair suitability for Class I, Division 2 /
Zone 2. Replace components only by the original types as follows:
● MCUP
Fuse: sand-filled fuse, 2 Amp. rated, type 522.720, manufactured by
ESKA (SICK part no. 2054541)
Processor board:
- Relays, type AZ830-2C-12DSE and AZ832-2C-12DSE, manufactured by
ZETTLER
- Back up battery, type BR2032, manufactured by PANASONIC
● Optional modules
Analog input and output modules as well as digital input modules as
listed on
p. 238, § 6.3.1.
Interface modules:
→
pg. 238, § 6.3.2
NOTICE:
The replacement of parts (relays and other electrical components) soldered
on the processor board is not permitted. The information is given purely in
order to check whether a
complete board to be replaced matches the