194 FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
Start-up and Parameter Settings
Subject to change without notice
4.3.5 Setting Interface module parameters
4.3.5.1 General information
The following steps are necessary to select and set the optionally available Interface
modules (
pg. 59, § 2.2.4, Optional modules):
Select device file "MCU-P", set the measuring system to "Maintenance" mode and enter
the Level 1 password (
pg. 161, § 4.1.4).
Select the "Parameter / System Configuration“ directory.
The Interface module installed is shown under "Interface Module - Type Selection".
Configure the Interface module according to requirements.
Fig. 130 "Parameter / System Configuration" directory
NOTICE:
Factory setting for counted flow direction is "positive flow".
GSD file and measured value assignment are available for the Profibus DP
module on request.