240 FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
Specifications
Subject to change without notice
Fig. 169 Sealing installation (designed by ”pikotek”), bolt torque values for grooved metal gasket B9A and polymer gasket
GYLON
Tightening torques
Default: Grooved metal gasket B9A
Option: Polymer gasket GYLON
Grooved metal gasket
B9A
Polymer gasket GYLON
Bolts 2“/DN50 3“/DN80 2“/DN50 3“/DN80
M16 A2/A4-70 126 Nm 126 Nm 126 Nm 126 Nm
5/8 A193 gr. B8m 84 Nm 84 Nm 118 Nm 118 Nm
5/8“ A320 gr. L7m
(A193 gr. B8m)
77 Nm 77 Nm 118 Nm 118 Nm
Thickness of gasket 4,25 mm 4,6 mm
No. of bolts 4 4 4/8 4