SIEMENS Energy & Automation 10-85
SIMOREG DC Master Base Drive Panel Operating Instructions
PNU
Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
r810
(G170)
Receive data on G-SST1
Display of data received via USS interface 1
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
Ind: 20
Type: L2
P052 = 3
r811
(G170)
Transmit data on G-SST1
Display of the data to be transmitted via USS interface 1
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
Ind: 20
Type: L2
P052 = 3
r812
(G171)
(G173)
Receive data on G-SST2
When USS protocol (P790=2) is selected:
Display of data received via USS interface 2
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
When peer-to-peer (P790=5) is selected:
Display of data received via peer-to-peer interface 2
i001: Receive data word 1
...
i005 Receive data word 5
i006: Not used
...
i020 Not used
Ind: 20
Type: L2
P052 = 3
r813
(G171)
(G173)
Transmit data on G-SST2
When USS protocol (P790=2) is selected:
Display of the data to be transmitted via USS interface 2
i001: Display process data word 1
...
i016 Display process data word 16
i017: Display parameter data word 1
...
i020: Display parameter data word 4
When peer-to-peer (P790=5) is selected:
Display of the data to be transmitted via peer-to-peer interface 2
i001: Transmit data word 1
...
i005 Transmit data word 5
i006: Not used
...
i020 Not used
Ind: 20
Type: L2
P052 = 3