SIEMENS Energy & Automation 10-91
SIMOREG DC Master Base Drive Panel Operating Instructions
PNU
Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
r959 Alarm parameter 7
Parameter alarms 7 (TB alarms 1)
If one of the alarms between 97 and 112 is generated, the corresponding
segment in the display lights up.
100 99 98 97
101
102
103
104
105106107108109110111112
Ind: None
Type: V2
P052 = 3
r960 Alarm parameter 8
Parameter alarms 8 (TB alarms 2)
If one of the alarms between 113 and 128 is generated, the corresponding
segment in the display lights up.
116 115 114 113
117
118
119
120
121122123124125126127128
Ind: None
Type: V2
P052 = 3
10.48 Device identification
r964 Parameters for device identification on the PROFIBUS
[SW 2.0 and later]
Display parameters to support overview and diagnosis of all nodes on the
PROFIBUS-DP during and after commissioning
(coding according to PROFIBUS profile V3)
i001: Display of the manufacturer of the
SIMOREG DC Master 6RA70 : SIEMENS = 42
i002: Display of device type: SIMOREG DC Master 6RA70 = 4110
i003: Display of the software version of the SIMOREG DC Master
6RA70
(see r060.001)
i004: Display of year of generation of the software of the SIMOREG
DC Master 6RA70: y y y y
(see r061.001)
i005: Display of the month and day of generation of the software of
the SIMOREG DC Master 6RA70: d d m m
(see r061.003 and r061.002)
i006: Display of the controlled axes of the SIMOREG DC Master
6RA70: 1
0 to 65535
1
Ind: 6
Type: O2
P052 = 1
10.49 Visualization parameters: Control and status word
r967 Display of control word 1
Visualization parameter for control word 1 (bits 0-15)
Identical to r650 (control word 1)
Ind: None
Type: V2
P052 = 3
r968 Display of status word 1
Visualization parameter for status word 1 (bits 0 - 15)
Identical to r652 (status word 1)
Ind: None
Type: V2
P052 = 3
10.50 Resetting and storing parameters,
list of existing and modified P and r parameters
P970
*
Restore factory setting
Reset parameters to factory setting (default)
0: Parameter reset: All parameters are reset to their original values
(factory setting). This parameter is then automatically reset to 1.
1: No parameter reset
Note: Function can also be selected by setting P051=21.
0 to 1
1
Ind: None
FS=1
Type: O2
P052 = 3
P051 = 40
Offline