Product description
1.2 Product highlights
13
Maximum industrial compatiblity for 24-hour continuous use in industrial environments
Independent product design with a user-friendly enclosure concept and front design
Rugged all-metal enclosure, coated over its entire surface (blue chromated) and/or
enameled on the outside to protect against corrosion and dirt
High EM compatibility for use in industrial, business and commercial areas
Maximum processor performance (in full configuration) without loss of performance
(throttling) at up to 40 °C ambient temperature
Dust protection through overpressure venting concept with front-side fan and dust filter
Low noise impact thanks to closed-loop fan
Protection against vibration and shock through corresponding drive cage (type B) and card
retainer
High productivity through fast data processing
12th generation Intel® processors: Core i9, Core i7, Core i5 or Core i3 up to 16 cores / 24
threads
Graphics controller (770) integrated in processor up to 4 K Ultra HD resolution
Maximum performance, e.g. through Intel R680E chipset, DDR5 memory with support of
dual channel technology
High data transfer rates, e.g. via PCI Express Technology Gen 4, USB 3.2 Gen 2x2 (20
Gbps), M.2 NVMe SSD
Powerful graphics cards for high-performance graphics processing (3D) as well as for
simulation and AI applications
Hard drives with a capacity of up to 4 TB for the storage of larger data volumes and
greater reliability
Solid-state drive with up to 1024 GB as a fast replacement for hard disk drives for
increased data security
Reduction in standstill times thanks to high system availability and security
Secure 24h operation (high MTBF, speed-controlled fans)
RAID1 configuration: Data mirroring on two drives (HDD or SSD), also in removable trays
(hot-swap) and optionally with additional SSD (for operating system)
Hot swap in the RAID system: Replacing the drive (HDD) during operation. The rebuild
process onto the hot-spare drive (HDD) starts automatically
3.5" HDD/HDD Enterprise or 2.5" SSD or M.2 NVMe SSD as RAID configurations
Rapid identification and replacement of the drive in the event of a fault thanks to alarm
displays for RAID configurations and unique numbering
Status display (front LEDs) for Ethernet; alarm display for fan, temperature, watchdog and
drives in RAID configurations
Remote control and remote maintenance through iAMT (Intel® Active Management