Technical specifications
9.4 Electromagnetic compatibility
147
9.4 Electromagnetic compatibility
See the note in "Applicability of technical specifications (Page 141)".
EN 61000-6-3; EN 61000-6-4;
CISPR 32, EN 55032 Class B; FCC Class A;
KS C 9832
EN 61000-3-2 class D, EN 61000-3-3
EN 61000-6-1; EN 61000-6-2; KS C 9835
Interference immunity on power
lines
± 2 kV; according to IEC 61000-4-4; burst
± 1 kV; according to IEC 61000-4-5; surge symm
± 2 kV; according to IEC 61000-4-5; surge symm
Noise immunity on signal lines
± 2 kV; according to IEC 61000-4-4; burst; length > 30 m
± 1 kV; according to IEC 61000-4-4; burst; length < 30 m
± 2 kV; according to IEC 61000-4-5; burst; length > 30 m
Immunity to discharges of static
electricity
± 4 kV contact discharge (according to IEC 61000-4-2)
± 8 kV air discharge; (according to IEC 61000-4-2)
Immunity to RF interference
• 10 V/m; 80 up to 2700 MHz
80% AM to IEC 61000-4-3
• 3 V/m; 2.7 to 6 GHz
80% AM to IEC 61000-4-3
• 10 V; 10 kHz up to 80 MHz
Immunity to magnetic fields
30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)
Workstation SIMATIC IPC RW-545A
Operating Instructions, 08/2023, A5E52943278-AA