Device maintenance and repair
8.3 Removing and installing hardware
134
8.3.4.3 Replacing the module of the redundant power supply unit 700 W
If a module of the redundant power supply unit is defective, you can continue to operate the
device until the device can be shut down in a controlled manner.
The replacement of one of the two modules of the redundant power supply unit can be
performed without shutting down the device.
Requirement
An original spare part, i.e. a module of the redundant power supply unit of the same type.
You can find information on spare parts under "Hardware accessories (Page 32)".
Procedure
1. Use the status display to determine which module is defective, see "Status displays of
power supply unit 700 W (2 modules, each 700 W, redundant) (Page 30)".
2. Disconnect the defective module from the line voltage.
Pull the power plug from the socket of the defective module.
3. Open the locking clipand pull out the module by the handle ③.
4. Insert the new module and push it to the rear edge of the enclosure until it clicks into place
there.
5. Re-insert the power plug into the socket of the newly inserted module.
6. Check the safe state of the device. Check the correct function on the status display.