Tables, data records
3.4 Tables, PROFINET data records
SIMOCODE pro - Communication
Function Manual, 11/2018, A5E40508495002A/RS-AC/003
247
48.0 Truth table 1 type 3I/1O Byte 0 -
11111111
0
49.0 Truth table 2 type 3I/1O Byte 0 -
11111111
B
0
50.0 Truth table 3 type 3I/1O Byte 0 -
11111111
0
52.0 Motor protection - Cooling down
period
Word 600 -
65535
100
ms
3000
IM UM(+)
54.0 Motor protection - Pause time Word 0 - 65535 100
ms
0 0 = disabled
IM UM(+)
56.0 Execution time Word 0 - 65535 100
10 0 = disabled
58.0 Monitoring the number of starts
Word 0 - 65535 1 s 0
60.0 Monitoring the number of starts
Word 0 - 65535 1 s 0
62.0 Motor stop time level > Word 0 - 65535 1 h 0
64.0 Timer 1 - Limit Word 0 - 65535 100
0
66.0 Timer 2 - Limit Word 0 - 65535 100
ms
0
68.0 Counter 1 - Limit Word 0 - 65535 0
70.0 Counter 2 - Limit Word 0 - 65535 0
72.0 EM+
2)
- trip level Word 30 -
1 mA 1000
74.0 EM+
2)
- warning level Word 30 -
1 mA 500
Motor protection - Set current
I
s
1
word
1)
10
mA
IM UM(+)
84.0 Motor operating hours level > D-
word
0 -
0xFFFFF
1 s 0
88.0
Reserved
D-
0
1) Value range dependent on current range of the IM / UM and the conversion factor
Bit 31 = 1, i.e. conversion factor active.
2) 3UF7510-1AA00-0 ground-fault module