Figure 7-7 Signal sequence for starting travel in "go to zero positions" mode
Section 1:
Select the "go to zero positions" mode by setting the "move_zero" control bit (STW1_PLC_TLS,
bit 14).
Section 2:
Activate the move command by setting the "move" control bit (STW1_PLC_TLS, bit 5).
TLS control function description
7.2 TLS modes and TLS functions
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA 245