Setup
3.5 Clamp protection
3-45
SINUMERIK 802D sl Operation and Programming Nibbling (BP-N), 06/2006 Edition
6FC5 398-3CP10-0BA0
Fig. 3-13 Defining protection zones
Use the <Abort> softkey to cancel.
Depending on the number of clamps, the following NC machine data must be changed:
MD 28200, MD 28210, MD 28212, MD 18190, MD 18890.
S Number of protection areas used
2 clamps: 3
3 clamps: 4
4 clamps: 6
S Number of elements used
2 clamps: 12 elements
3 clamps: 16 elements
4 clamps: 24 elements
3.5.1 Protection zone for two clamps
The parameters refer to a defined reference point (workpiece zero).
Table 3-4 Parameters for two clamps
Parameter
Meaning
x X position of the clamp
y Y position of the clamp
w Clamp width
a Clearance between clamps 1 and 2
e Clamp safety clearance
f Clamp holder safety clearance