10.03
6-193
Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Start-up required for axis %1, drive %2
%1 = NC axis number
%2 = drive number
This alarm occurs during initial start-up when there is no valid 611D machine
data available.
NC not ready.
Mode group not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
Please inform the authorized personnel/service department.
S Reset motor data.
S Back up boot drive.
S Power up system again
Switch control system OFF and ON again.
Axis %1, drive %2 drive basic clock cycle invalid
%1 = NC axis number
%2 = drive number
The drive basic clock cycle set on the NC is too high for the drive.
NC not ready.
Mode group not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
No remedial action is required. After the system has powered up again, the
NCK machine data relevant to the drive basic clock cycle, i.e.
MD 10050: SYSCLOCK_CYCLE_TIME (basic system cycle) and MD 10080:
SYSCLOCK_SAMPL_TIME_RATIO (scale factor of position controller cycle for
actual value sensing) are automatically altered so that the relevant limits are
applied.
Switch control system OFF and ON again.
Axis %1, drive %2 drive basic clock cycle axially unequal
%1 = NC axis number
%2 = drive number
The drive basic clock cycle is different for the two axes on a 2-axis module.
This alarm can only occur with OEM users who have the 611D drive without the
standard NCK interface. In this instance, it is possible to transfer different axial
drive clock cycles to the 611D modules.
300 701
Explanation
Response
Remedy
Continue program
300 702
Explanation
Response
Remedy
Continue program
300 707
Explanation
6 Hydraulics Diagnostics
02.99

Table of Contents

Other manuals for Siemens Sinumerik 840D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840D Series and is the answer not in the manual?

Siemens Sinumerik 840D Series Specifications

General IconGeneral
AxesUp to 31 axes
Power Supply24 V DC
Control TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
PLCIntegrated PLC (programmable logic controller)
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
Max. Number of ChannelsUp to 10 channels