10.03
6-203
Siemens AG, 2003. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
See drive functions “FB / DB1” MD1002
Switch control system OFF and ON again.
Axis %1, drive %2 velocity controller clock cycle axially unequal
%1 = NC axis number
%2 = drive number
The speed controller cycle MD 5001: SPEEDCTRL_CYCLE_TIME must be
identical for both axes.
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
Set velocity controller clock cycle in MD 5001: SPEEDCTRL_CYCLE_TIME to
an identical value for both axes.
Switch control system OFF and ON again.
Axis %1, drive %2 monitoring cycle axially unequal
%1 = NC axis number
%2 = drive number
On 2-axis modules, the monitoring cycle set in MD 5002:
MONITOR_CYCLE_TIME (monitoring cycle) must be identical for both axes.
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
MD 5002: MONITOR_CYCLE_TIME (monitoring cycle) to an identical value for
both axes.
Switch control system OFF and ON again.
Response
Remedy
Continue program
310 704
Explanation
Response
Remedy
Continue program
310 705
Explanation
Response
Remedy
Continue program
02.99