Operators Tools
7-497SJ62 Manual
C53000-G1140-C121-1
ated causes are listed in Table 7-4, together with other messages for the control of de-
vice functions.
Table 7-4 Possible Control Messages
Message Text Message Cause
6\VWHP(UURU Interruption by system error
0DQ2YHUZULWH2. Return routing carried out
0DQ2YHUZULWH)DLO Return routing cannot be carried out
&RQWURO$ERUW2. Command interruption carried out correctly
&RQWURO$ERUW)DLO Process cannot be interrupted because no command is issued,
command runs in different switching direction, or interruption is not
planned or set up.
&RQWURO([HFXWHG Command was correctly executed and ended
&RQWURO)DLOHG Refusal because the command number or the origination source is
not permitted
,QWHUORFNHG Refusal because the communication interface was blocked or the
command object is blocked by a protective function.
6ZLWFKJU,QWORFNHG Refusal because the command object is subject to field interlock-
ing
6ZLWFKLQ3RVLWLRQ Refusal because the present switch position = command direction
6HWWLQJ(UURU Refusal because of a parameter fault, such as unknown command
type
1RW$XWKRUL]HG Command from ON-SITE refused because command object is
subject to switching authority, which is set to REMOTE
&RQWURO([SLUHG Refusal because command is too old (expiry monitor)
1R&RQWURO'HYLFH Information address is not planned as command output
&RQILJ(UURU Refusal because no relay is assigned to this object, or the relay
jumpered in the device does not exist
&RQWURO%ORFNHG Refusal because an output block is set
6\VWHP2YHUORDG" Refusal because a relay to be controlled is already active (e.g., by
another command)
6:WRQHUURU" Refusal because another relay is already controlled
6\VWHP2YHUORDG No more free timers available
8SSHU6HWW/LPLW For transformer LTC step commands, highest level already
reached
/RZHU6HWW/LPLW For transformer LTC step commands, lowest level already reached
([HFXWLQJ&RQWURO New command refused because a command is already in process-
ing
&RPPDQG7LPHRXW Feedback indication missing
%LQDU\,QS,JQRUHG Recording block set
&KDWWHU$FWLYH Flutter block is active
6HWW&KDQJH$FWLYH Refusal because parameter loading process is running
6WDWXV&KDQJH2. Status FRPPDQGH[HFXWHG
6WDWXV&KDQJH)DLO Status command cannot be executed
&KDQJH2. Marking executed
&KDQJH)DLOHG Marking cannot be executed
www . ElectricalPartManuals . com

Table of Contents

Other manuals for Siemens SIPROTEC 7SJ62

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7SJ62 and is the answer not in the manual?

Siemens SIPROTEC 7SJ62 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7SJ62
CategoryRelays
LanguageEnglish

Related product manuals